AH505

SPECIFICATIONS

ELECTRICAL
(TA = +25°C, Vcc = +/- 15VDC unless otherwise noted)
PARAMETER CONDITION MIN TYP MAX UNITS
INPUT
Voltage 0.1 +10 V
Resistance 1 KΩ
Reset Command Voltage 2 5 V
Gate Open 2 5 V
Peak Sense Command Voltage 0 0.8 V
Command Load 1.5 2
RATED OUTPUT
Voltage 10 V
Current 10 MA
Output Resistance 10 Ω
DYNAMIC RESPONSE
Continuous Sinusoidal 20 MHz
Acquisition Time 10V Step 60 nsec
  1V Step 45 nsec
Reset Time 50 nsec
Gate Turn On Time 30 nsec
Gate Turn Off Time 30 nsec
Memory Delay Rate 10 mV/μs
INPUT ERROR
Offset Voltage 30 MV
Gain Error 2 %
Sensing Error 2 %
POWER SUPPLY
Rated Voltage +/-9 +/- +/-18 V
Current, Quiescent 15 mA
 
TEMPERATURE RANGE
Operating -55 +85 °C
Storage -65 +100 °C
Thermal Resistance °C/W
Quiescent Rise* °C
Quiescent Rise is temperature above ambient
 
Absolute Maximum Ratings
Supply +/-18VDC
Input Voltage1 0 to +10V
Storage Temperature Range -65°C to 100°C
Operating Temperature Range -55°C to 85°C
Lead Temperature (Soldering 10 seconds) +300°C
 
Notes
1) For supply voltages less than +/-15V DC, the absolute maximum input is equal to the supply voltage.